High Frequency Electrostatic Eliminator Ionizing Air Bar KE-X Series
Model : KE-X Series
Features :
-
High-Frequency Operation: Operates with a high-frequency exchange, reaching up to 68,000 Hz for efficient static elimination.
-
Automatic Ion Balance System: Ensures precise ion balance for consistent performance.
-
Easy Assembly: Power supply features side wiring, simplifying the installation process.
-
High-Pressure Alarm: Equipped with an abnormal high-pressure alarm indicator for enhanced safety.
-
Adjustable Maintenance Settings: Maintenance timing can be customized based on the workshop environment.
-
Adjustable Static Elimination: Both static elimination speed and airflow can be fine-tuned by adjusting the valve, allowing for optimized performance.
Model
|
Overall length A (mm) | Installation interval B (mm) | Installation interval C (mm) | Installation interval D (mm) | Static elimination (mm) | Electrode spacing F (mm) |
KE-36X | 413 | 326 | 391.2 | 398.8 | 360 | 180 |
KE-60X | 653 | 566 | 631.2 | 638.8 | 600 | 420 |
KE-84X | 893 | 806 | 871.2 | 878.8 | 840 | 660 |
KE-108X | 1133 | 1046 | 1111.2 | 1118.8 | 1080 | 900 |
KE-132X | 1373 | 1286 | 1351.2 | 1358.8 | 1320 | 1140 |
KE-156X | 1613 | 1526 | 1591.2 | 1598.8 | 1560 | 1380 |
Technical Parameters :
Category | Parameters | Category | Parameters |
Input | DC24V | Air Volume | 2.44-5.1m3/min |
Ion balance | 0±20V | Ozone Concentration | Below 0.004ppm(distance 50mm) |
Clean timer set | 0-999 hours | Environment Temperature | 0-40 degree |
Static Voltage | High Frequency AC method /_+2200v | Temperature Humidity | 15-70%RH (no water drop condensation) |
Decay time | 2.0S (testing distance 300mm, supply air 0.2 MPa) | Air presure apploication | 0.1-0.5 MPa |
range( MPa) | |||
Weight | 1kg (including bracket) |
Anti-static test condition
|
|||
Working voltage : DC 24V | Test voltge : ± 1000v - ± 100V Evironment temperature: 23°C ± 2℃ | Test voltge : ± 1000v - ± 100V Evironment temperature: 23°C ± 2℃ | |
Distance | Decay time(Postive /positive ) | Ion balance | Notes: |
300mm | 0.8s | 0±20v | 1: Test meters : TREK156A |
600mm | 1.5s | 0±20v | 2:Decay time from ±1000V ±100V; |
900mm | 3.5s | 0±20v | 3: Use KE-60X no decline airflow with air pressure of o.20Mpa and 0.5Mpa respectively. |