High Frequency Ionizing Air Bar Static Elimination KE-36X



Model : KE-36X

 


Features : 
 
  • High-Frequency Operation:
    Utilizes high-frequency exchange technology with a frequency up to 68,000 Hz, ensuring efficient performance.

  • Automatic Ion Balance System:
    Ensures precise ion balance for optimal static elimination.

  • Easy Assembly:
    Features side wiring for the power supply, making assembly quick and convenient.

  • Abnormal Pressure Alarm:
    Equipped with a high-pressure abnormal alarm indicator to alert operators to any issues.

  • Customizable Maintenance Timing:
    Maintenance schedules can be set according to the workshop environment for added flexibility.

  • Adjustable Airflow for Static Elimination:
    Both static elimination speed and airflow can be controlled by adjusting the valve, providing precise control over the process.






 


Applications : 


 


Technical Parameters : 
 
Category
Parameters Category Parameters
Input DC24V Air Volume 2.44-5.1m3/min
Ion balance 0±20V Ozone Concentration Below 0.004ppm(distance 50mm)
Clean timer set 0-999 hours Environment Temperature 0-40 degree
Static Voltage High Frequency AC method /_+220~240V Temperature  Humidity 15-70%RH (no water drop condensation)
Decay time 2.0S (testing distance 300mm, supply air 0.2 MPa) Air presure apploication 0.1-0.5 MPa
range( MPa)
Weight 1kg (including bracket)    


 
 
Model
Overall length A Installation interval B Installation interval C Installation interval D Static elimination Electrode spacing F
(mm) (mm) (mm) (mm) (mm) (mm)
KE-36X 413 326 391.2 398.8 360 180
KE-60X 653 566 631.2 638.8 600 420
KE-84X 893 806 871.2 878.8 840 660
KE-108X 1133 1046 1111.2 1118.8 1080 900
KE-132X 1373 1286 1351.2 1358.8 1320 1140
KE-156X 1613 1526 1591.2 1598.8 1560 1380
 
 
 
Anti-static test condition
Working voltage : DC 24V  Test voltge : ± 1000v - ± 100V Evironment temperature: 23°C ± 2℃
Distance Decay time(Postive /positive ) Ion  balance Notes:
300mm 0.8s 0±20v 1: Test meters : TREK156A
600mm 1.5s 0±20v 2:Decay time from ±1000V ±100V;
900mm 3.5s 0±20v 3: Use KE-60X no decline airflow with air pressure of o.20Mpa and 0.5Mpa respectively.

Make Appointment

We would be more than happy to solve your problem and question, please arrange your appointment with us.